This cable as far as I remember doesn't come with a driver. It should be installed if you have recent version of MICROWIN or even WinCC flexible. This cable is used for download or upload of S7-200 PLCs and also some SIMATIC Panels. In any case, there may be some difficulties with some old versions CPU. Please revise the info in the following FAQ. Siemens Industry Online Support.
- 6es7901 3db30 0xa0 Driver Free Download 64 Bit
- 6es7 9013db300xa0 Driver Free Download 64-bit
- Audio Driver Free Download
- 6es7 9013db300xa0 Driver Free Downloads
- Usb Driver Free Download
- 6es7901 3db30 0xa0 Driver Free Download For Windows 10
- 6es7 9013db300xa0 Driver Free Download Windows 10
1,103 drivers total Last updated: Feb 27th 2019, 07:20 GMT RSS Feed
sort by:
Epson WorkForce Pro WF-8090 Printer PS3 PostScript Driver 1.20 64-bit
3,492downloads
Epson WorkForce Pro WF-8090 Printer Driver 2.46 64-bit
632downloads
Epson WorkForce Pro WF-8090 Remote Print Driver 1.66 64-bit
238downloads
Epson WorkForce Pro WF-8090 Printer PS3 PostScript Driver 1.30 for Mac OS
105downloads
Epson WorkForce Pro WF-8090 Remote Print Driver 9.44 for Mac OS
83downloads
Epson WorkForce Pro WF-8090 ICA Scanner Driver 5.8.6 for Mac OS
783downloads
Epson WorkForce Pro WF-8090 Scanner Driver/Scan Utility 5.2.2.2 for Mac OS
413downloads
Epson WorkForce Pro WF-8090 Printer Driver 9.81 for Mac OS
70downloads
6es7901 3db30 0xa0 Driver Free Download 64 Bit
May 25th 2017, 15:24 GMTEpson WorkForce Pro WF-8090 Printer Driver/Utility for Mac OS
34downloads
Epson WorkForce Pro WF-8090 Printer Firmware HA28GC
44downloads
6es7 9013db300xa0 Driver Free Download 64-bit
Epson WorkForce Pro WF-8090 Printer PS3 PostScript Driver/Utility
49downloads
Epson WorkForce Pro WF-8090 Printer PS3 PostScript Driver 1.20
138downloads
Epson WorkForce Pro WF-8090 Printer Driver/Utility
69downloads
Epson WorkForce Pro WF-8090 Scanner Driver/Scan Utility 5.2.2.1
721downloads
Epson WorkForce Pro WF-8090 Printer Driver 2.46
59downloads
Epson WorkForce Pro WF-8090 Remote Print Driver 1.66
41downloads
Epson WorkForce Pro WF-C869R Printer Driver 9.86 for Mac OS
47downloads
Audio Driver Free Download
May 24th 2017, 13:45 GMTEpson WorkForce Pro WF-C869R Scanner Driver/Scan 2 Utility 6.2.2 for Mac OS
211downloads
Epson WorkForce Pro WF-C869R Printer Driver 2.61 64-bit
158downloads
Epson WorkForce Pro WF-C869R Printer Postscript 3 Driver 1.12 64-bit
35downloads
Epson WorkForce Pro WF-C869R Remote Print Driver 1.66 64-bit
31downloads
Epson WorkForce Pro WF-C869R Printer Driver 2.61
70downloads
6es7 9013db300xa0 Driver Free Downloads
May 24th 2017, 12:33 GMTEpson WorkForce Pro WF-C869R Printer Postscript 3 Driver 1.12
38downloads
Epson WorkForce Pro WF-C869R Printer Driver/Utility
45downloads
Epson WorkForce Pro WF-C869R Remote Print Driver 1.66
47downloads
Epson WorkForce Pro WF-C869R Scanner Driver/Scan 2 Utility 6.2.5.0
564downloads
Epson WorkForce Pro WF-8590 Printer PS3 PostScript Driver 1.20 64-bit
41downloads
Epson WorkForce Pro WF-8590 Printer Driver 2.46 64-bit
39downloads
Epson WorkForce Pro WF-8590 Remote Print Driver 1.66 64-bit
71downloads
Usb Driver Free Download
May 24th 2017, 09:37 GMT6ES7901-3DB30-0XA0
Siemens s7-200plc multi-master ppi programming cable with isolated usb interface, directly use the usb interface in step7microwin software, no need to install drivers, support ppi, multi-master ppi, advanced ppi protocol, support 187.5 kbps high-speed communication, with communication indicator.
6ES7901-3DB30-0XA0 is an intelligent multi-master PPI programming cable (PPI Multi-Master Cable) with USB interface, which realizes level conversion from USB to RS485 and various PPI protocol conversion. At present, many cheap USB/PPI on the market communicate by converting USB into virtual serial port (COM port), commonly known as “pseudo USB interface”. This kind of cable is only a level conversion from USB to RS485 and can only support ordinary PPI protocol. . And USB/PPIM+ is a real USB interface cable, no need to install driver, directly use the USB option in STEP7 Micre/WIN software, support PPI, advanced PPI (Advanced PPI), multi-master PPI (Multiple Master Network) protocol, Support 187.5Kbps high-speed communication, and can hold tokens in multi-master PPI network.
This cable is 100% compatible with the original Siemens USB multi-master cable 6ES7 901-3DB30-0XA0. The difference is that the working power source is taken from the USB port of the computer and is powered by DC/DC isolation. It is no longer powered by the PLC port. It is easy to extend the communication distance of RS485 terminal without considering power supply. The light-emitting diode on the conversion box indicates the status of data transmission and reception.
6ES7901-3DB30-0XA0 can communicate with S7-200PLC and also supports communication with Siemens touch screen.
The 6ES7901-3DB30-0XA0 cable is an optically isolated cable for industrial design. It is equipped with surge protection and lightning protection circuits on both RS485 and USB ports. It can be plugged and unplugged at will. It is suitable for Siemens S7-200 series PLC , It is especially suitable for industrial sites where the communication port is easily damaged due to large interference. Various protection measures in the circuit ensure the safe operation of the system.
How to use 6ES7901-3DB30-0XA0
Software Step 7 Microwin Siemens
1,Enter the “Set PG/PC interface” in STEP7 Micro/WIN programming software, select the “PC/PPI cable (PPI)” item and click the “Properties…” button.
2,Select the “USB” option in the drop-down box of “Local Connection”.
6es7901 3db30 0xa0 Driver Free Download For Windows 10
3,Set the following settings in the Station Parameters setting of “PPI”: Address: 0, Timeout: 1s.
In the Network Parameters setting of “PPI”, you can choose any of the following communication protocols according to your needs:
Advanced PPI: check the Advanced PPI check box;
Multi-master PPI: check the Multiple Master Network check box;
Normal PPI: Do not check the above two check boxes, this is the default option.
6es7 9013db300xa0 Driver Free Download Windows 10
Select a baud rate in the baud rate drop-down box to make it the same as the baud rate of the PLC. If you do not know the baud rate of the PLC, you can choose a value at will.
Click the “OK” button to return to the main menu interface.
4,Click the “Communication” button on the main menu interface to enter the PLC connection interface, check the “Search all baud rates” check box, and then double-click “Double-click to refresh”, after a while, the PLC model and address connected to the cable will appear Wait for information, which means that a connection has been established with the PLC. After clicking the “Confirm” button, you can upload, download the program and monitor it.